ricardo series engine 2100D for 11kva diesel generator
Product Description
Main specification of 11kva Diesel Generator
a,3-Phase, 50Hz@1500RPM, 400/230V (Also Can Be Made According To Customers’ Special Requirements)
b,12V/24V DC start motor and storage battery
c,Brushless, Self-excited, IP23, insulation class H alternator
d, 40°C radiator as standard, 50°C is optional
e,Key start panel control system as standard, digital auto-start panel is optional
f,All Generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load, 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop).
Main technical parameters
Rated power | 9kw/11kva |
Model | HR-9GF |
Type | open type,soundproof,weather proof type, mobile type as your required |
Rated voltage | 400/230V,240/120V etc,as required |
Rated frequency | 50Hz/60HZ. |
Rated current | 16A |
Rated speed | 1500/1800rpm |
Connection type | single phase or 3P4W |
Voltage governor | AVR |
Start method | electric start |
Engine data:
Diesel Engine | |
Brand | Ricardo |
Model | HT2100D |
Number of Cylinders | 2 in line |
Rated Power(kw) | 14kw |
Cycle | 4 stroke |
Aspiration Type | natural |
Bore*Stroke | 100*115 |
Displacement(L0 | 1.8 |
Speed Governor | Mechanical |
Lub Oil Capacity(L) | 6.5 |
Rated Fuel Consumption(L) | 2.6 |
Type | Direct Injection |
Speed Governor | Electrical |
Cooling System | Water-cooled |
Rotating Speed | 1500/1800RPM |
Fuel Consumption at 100% Load | 208g/kw.h |
Starting Method | Electrical starting |
Brushless alternator Specification:
Alternator Brand | Stamford,Engga,Mecc-alte,Marathon ... |
Exciter Type | Brushless, Self-excited |
Rated Speed | 1500/1800rpm |
Rated Frequency | 50/60hz |
Phase | three or single |
Rated Voltage | 400V (Available with customer requirements) |
Power | 0.8 |
Voltage Adjust Range | ≥5% |
Protection Grade | IP23 |
Insulation Grade | H |
Compliance with GB755,BS5000,VDE0530,NEMA MG1-22,IEC-34,CSA C22-100and AS1359 standards
Digital Control System
1)Control box with Ammeter,Voltmeter,Frequency Meter,Water temperature,Oil Pressure ,Hour counter,Phase TransferSwitch, CircuiBreaker,Indicator Light for power, generating & emergency. protection system with module for over speed,high temperature,low oli pressure.
2)LED contorl panel
Accessories
1) Standard accessories: Standard 40 radiator mounted on skid, Common steel frame, circuit breaker, damper, exhaust silencer, flexible pipe, battery and connecting wires, Standard tools kit, operation manual and document.
2) Optional accessories: Engine coolant and oil heater, alternator space heater, cooling for heat exchanger, communication interface, battery charger by main supply, daily fuel tank, ATS and paralleling system, soundproof canopy and moving trailer.
Standard configuration:
1) Starting system: DC alternator is used to start engine
2) Short circuit protection: MCCB air switch
3) Cooling system: combined cooling water tank fitted to meet the
requirement of radiation at ambient temperature 40°C
4) Filter system: oil, fuel and air filter
Optional type:
Other generators:
Warranty:
12 months or 1500 running hours from shipment date.
If the quality problem arise during the warranty period,and verified the problem is caused by our genset-body instead of external or natural reasons.
(Refer to all kinds of natural disaster, shipping, loading, unloading, wrong-operation, etc),
we will supply the relevant Spare Parts free of charge for maintenance;
after the warranty period, we can supply the required spare parts for you under cost prices
Warm welcome you to visit our factory:
To be the best partner of electric power equipment
Our advantage:
Use Manual:
1. Operators need to be familiar with the operation of generating sets, operating methods, and all control bodies, manual valves, stopping body position.
2. In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1) Units exist electric shocks danger;
(2) Units exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4. Engine room or other nearest should maintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers). 5. Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6. Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7. Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dc power supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be notified stop all of this unit operation.
9. To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10. Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.
Product Categories : Diesel generator set > Ricardo Generator